Enter the fence run length, max post spacing, corners/ends, and gates. Get section count, even spacing, and total posts — with optional line vs brace breakdown.
Use this when ordering T-posts or wood line posts for a straight (or segmented) run. Field fence often spaces 8-12 ft; tighter spacing on curves and high pressure.
Each gate typically needs two stout posts (hinge and latch). Corners and ends are brace assemblies — count them separately from light line posts.
Post count is driven by run length and spacing, then corners, ends, and gate posts that do not fall on the even spacing grid. Order a few spares — rocky ground and brace assemblies eat extras.
Line-post spacing for livestock wire is often 8–12 ft; high-tensile may stretch farther. Always follow your fence design and local codes for highway or boundary work.
Fenceable length = run - gate openings. Sections = ceil(fenceable / max_spacing). Even spacing = fenceable / sections. Line posts between braces approx sections - 1. Total posts = line + corners + ends + 2 x gates.
fenceable = max(0, run - gate_openings)
sections = ceil(fenceable / max_spacing)
even_spacing = fenceable / sections
line_posts ≈ max(0, sections - 1)
gate_posts = gates x 2
total = line_posts + corners + ends + gate_posts
A full perimeter needs four corners and multiple runs — calculate each run or sum carefully. Brace assemblies may use 2-3 posts per corner in the field; enter what you will buy.
660 ft run, 10 ft max spacing, one 12 ft gate: fenceable 648 ft → 65 sections → spacing ≈ 9.97 ft. Line posts ≈ 64. Plus 4 corners + 2 gate posts → ≈ 70 posts (before extra brace posts).
Second example: A 1,320 ft run (1/4 mile) at 10 ft spacing needs 1,320 ÷ 10 = 132 spaces → 133 line posts if both ends are already counted as corners/ends. Add separate counts for corners, gate posts, and brace assemblies.
Assumptions: single straight run; uniform max spacing; gate openings removed from line-post span.
Limits: curves, drops, and water gaps need closer posts; H-braces add posts beyond one corner.
Responsibility: verify manufacturer spacing for woven wire tension and local codes.
T-posts often 8-12 ft on cattle fence; wood line posts may be wider with stays. Use your wire maker's chart.
Ceil to max spacing, then divide evenly so the last gap is not a short orphan.
Count the main corner post here; add dedicated brace/deadman posts in the corner count if you buy them as separate sticks.
Run this calculator once per side (or once with total perimeter as run and corners = 4).
Treat corners/ends/gates as fixed, then space line posts evenly between them — the calculator’s even-spacing output is for that middle run.
Each brace assembly usually needs extra posts beyond a single corner post. Add them to the spare/brace count rather than relying on line spacing alone.